There are a number of differences in functionality between WebStation and WorkStation.

Table: WebStation and WorkStation Differences

Function

WorkStation Standard a

WorkStation Pro b

WebStation

Dashboards

View dashboards

-

-

X

Create and edit public dashboards

X c

X c

X

Create and edit personal dashboards

-

-

X

View slide shows

-

-

X

Create and edit slide shows

X

X

X

Develop custom dashboard components

-

X

-

Alarms

View alarms

X

X

X

Manage alarms

X

X

X

Edit alarms

X

X

X d

Create alarms

X

X

-

Support for flashing and audible alarms

X

X

-

Create and edit alarm filters

X

X

X

View events

X

X

X

BACnet

View priority array

X

X

X

Edit priority array

X

X

X

Create devices (includes device discovery)

X

X

-

Manage BACnet backup and restore

X

X

-

Graphics

View graphics

X

X

X

Create and edit graphics

-

X

-

View graphics that use client API

-

-

X

Create graphics that use client API

-

X

-

Trend Logs and Extended Trend Logs

View trend logs

X

X

X

Edit trend logs

X

X

X e

Create trend logs

X

X

X f

View multi trend log lists

X

X

X

Create and edit multi trend log lists

X

X

-

Export multi trend log lists

X g

X g

X h

View extended trend logs

X

X

X

Edit extended trend logs

X

X

X e

Create extended trend logs

X

X

-

LonWorks

Create devices (includes device discovery)

X

X

-

Manage devices

X

X

-

View Network Variables (NVs) and Configuration Parameters (CPs)

X

X

X

Edit NVs and CPs

X

X

X

Modbus

Create devices

X

X

-

Manage devices

X

X

-

View values

X

X

X

Edit values

X

X

X

Point Values

View values

X

X

X

Edit values (for example, change a setpoint)

X

X

X

Programs

Create and edit customized programs

-

X

-

View Function Block program in Graphics Viewer

X

X

-

Reports

View reports

X

X

X

Edit reports

X

X

X i

Create and configure reports

X

X

-

Schedules and Calendars

View schedules and calendars

X

X

X

Edit schedules and calendars

X

X

X j

Create schedules and calendars

X

X

-

Users and User Groups

Create and edit users

X

X

X k

Create and edit user group membership

X

X

X k

Create and edit user groups

X

X

-

Create and edit permissions

X

X

-

User Experience

View customized workspaces

X

X

X

View customized navigation panes

X

X

X

Log on as Windows Active Directory user

X

X

X

Automatic guest account log on

X

X

X

Password management

X

X

X

View saved searches

X

X

X

Create and edit saved searches

X

X

-

Simple and advanced searches

X

X

X

Kiosk mode

-

-

X

Bookmark views (web page URLs)

-

-

X

Bookmark favorite pages

-

-

X

Support for localization

X

X

X

Support for translation

X

X l

X

Ability to change language on the client side

X

X

X

Use personal layout and filter favorites

X

X

X

Create and edit personal layout and filter favorites

X

X

X

Support for Dark Mode

-

-

X

Support custom accent color

-

-

X

Other

Configure and edit I/O points, field buses, and communication ports

X

X

-

Create and edit logical structure

X

X

-

Create and edit views, panels, workspaces, and navigation panes

X

X

-

View and configure Watch pane

X

X

X

Administer backup and restore of database

X

X

-

Manage archiving

X

X

-

  1. WorkStation software without Graphics Editor, Script Editor, and Function Block Editor.
  2. WorkStation software including Graphics Editor, Script Editor, and Function Block Editor.
  3. Non-visual editing only.
  4. Can edit alarm ranges, text, delay times, shunt variables, assignments, and deadband.
  5. Can only change parameters, for example, interval time.
  6. Can only create interval trend log type.
  7. Export to XML, CSV, and Excel files supported.
  8. Export to Microsoft Excel file supported.
  9. Can edit some parameters per report, can save changes or make a copy of the report with changes.
  10. Can edit only existing schedules and calendars.
  11. Cannot assign permissions.
  12. Excluding Graphics Editor, Script Editor, and Function Block Editor.