Forcing a User to Change the Password at Next Logon

You force a user to change the password at next logon to increase the security, for example, when distributing a user account to a new user.

显示更多
action_close

As a WorkStation administrator, you can change users’ passwords, force users to change their passwords at next logon, or enable and disable the possibility for users to change their passwords.

Passwords are managed at the user account group level. Building Operation applies password changes to all user accounts that belong to the user account group.

注释:
  • If you are an administrator and have forgotten your password, contact the Building Operation support team.

To force a user to change the password at next logon
  1. In WorkStation, on the Tools menu, click Control Panel .

  2. On the Control Panel toolbar, select the SmartStruxure server.

     
    action_zoom_plus_stroke
  3. Click Account management .

  4. In the Domain list box, select the domain the user account belongs to.

     
    action_zoom_plus_stroke
  5. In the User Accounts list, select the user account.

  6. Click Summary .

  7. In the Force password change box, select True to force the user to change the password at next logon.

     
    action_zoom_plus_stroke
  8. Click the Save button

     
    action_zoom_plus_stroke
    .

The Force password change box is automatically set to False when the user changes their password.

  • User Accounts and User Account Groups
  • User Account – Summary Tab
  • Password Administration