Enterprise Server

arrow1_rotation简介 arrow1_rotation特点 arrow1_rotation规格
 
action_zoom_plus_stroke Enterprise Server
图: Enterprise Server

简介

EcoStruxure BMS 服务器是系统的核心,负责执行关键功能,比如控制逻辑、趋势记录和报警监测。Enterprise Server 收集站点范围内的数据以进行聚合和归档,并通过工作站或 WebStation 作为 Schneider Electric 的智能楼宇管理系统 EcoStruxure BMS 的单一管理点。

特点

Enterprise Server 是 EcoStruxure BMS 架构的中心点,通过它,用户可以配置、控制和监视系统。

Semantics

Enterprise Server and Enterprise Central come with built-in support for modelling of the “digital twin” of the building, site, campus, and region using Brick Schema. WorkStation and WebStation provide enhanced human understandability through the additional context that is given to alarms and points through the “digital twin”. The required graph database is included in the installation packages. WorkStation can be used to create the model, or it can be imported using the graph database user interface.

网络动力室

Enterprise Server 可使用各种协议运行多个控制程序。它可以管理报警、用户、时间表和趋势日志。来自 Enterprise Server 的数据可直接交付给用户或者站点或企业内部的其他 EcoStruxure BMS 服务器以及现场设备。

系统的全局视图

整个站点,包括所有自动化服务器及其关联设备,可通过 Enterprise Server 访问和配置。

该站点总览提供更容易批量更改的工程和数据分析。Enterprise Server 还聚合来自所有关联的自动化服务器设备的事件和报警数据。趋势日志可通过使用扩展趋势日志来聚合。

Text and graphics-based programming tools

Unique to the industry, the EcoStruxure BMS servers have both Script and Function Block programming options. This flexibility helps assure that a suitable programming method can be selected for the application.

集中化的报警和数据管理

站点内多台设备的报警,包括自动化服务器,均由 Enterprise Server 收集用于集中记录、显示和管理。用户还可查看多台服务器的事件日志和趋势日志。

Enterprise Server 托管历史和配置数据库。这些数据库存储了当前信息,包括趋势、报警、用户活动和属性信息。报警可触发电子邮件、SNMP、文件或客户端通知,可包括报警、点值或趋势日志数据。通知可通过时间表或其他二进制数值定期触发。

EcoStruxure BMS servers can be configured to automatically store all historical data, trend log data, event log and audit trail data, in an external database. If data needs to be available for longer periods of time, an external log storage can be incorporated into the EcoStruxure BMS without the need for extensive engineering work. The supported databases are TimescaleDB, which is built on PostgreSQL, and Microsoft SQL Server. The data in the external log storage is available natively to the viewers built into the EcoStruxure Building Operation clients and to the built-in reporting functionality.

You can use the powerful Log Processor functionality for custom processing of trend data for viewing in charts, dashboards and for inclusion in reports. The Log Processor enables advanced calculations on one or multiple trend logs and point values.

Examples of advanced calculations:

  • Energy usage normalization

  • Virtual submeters and summaries

  • Calculation of Mean Kinetic Temperature

  • Unit conversions

  • Average, maximum, and mini m um over custom periods

The output of the Log Processor can be saved in the database, including the External Log Storage or calculated automatically on demand.

From EcoStruxure Building Operation version 5.0.3 and later, selected trend logs and the event log can be sent to AVEVA PI System directly without the need for intermediate storage or specialized PI System connectors.

Reporting

The EcoStruxure BMS servers provide built-in functionality for basic reporting that can deliver reports in any text format and XLSX, without any dependencies to other external software. Reports for XLSX can be enriched by using advanced functionality such as formulas, conditional formatting, charts and sparklines.

Reports can be generated on schedule, on an alarm event or other custom conditions, and you can get the output delivered via email or written to file.

Using Enterprise Server and Enterprise Central, reports can be converted to PDF, and you can elevate the data security and traceability even further by using the optional add-on for automatically signing PDF reports with a digital certificate upon generation. This validates that the content has not been altered after the report was generated.

Authentication and permissions

An EcoStruxure BMS provides a powerful permission system that is easy to manage, flexible, and adapts to all kinds of system sizes. The permission system provides a high standard of authentication. Authentication is done against the built-in user account management system , against Windows Active Directory Domains , or via SAML 2.0 single sign-on . The built-in account management system allows an administrator to establish password policies that meet stringent cybersecurity guidelines. When Windows Active Directory or SAML 2.0 authentication is used, the administration costs are lower because users do not have to be managed in multiple directories.

高级活动日志

比基础活动记录得更多是非常重要的。在 EcoStruxure BMS 中,每次操作的记录都有时间戳、执行操作的用户,以及被更改的数值。

WorkStation/WebStation 界面

经由任何客户端进入的用户所获得的体验都是相似的,无论用户登录到哪个 EcoStruxure BMS 服务器。用户可以直接登录 Enterprise Server,以设计、调试、监督和监控自动化服务器及其连接的中央 IO 模块和现场总线设备。如需了解更多信息,参见 WorkStation 和 WebStation 规格表。

开放楼宇协议支持

EcoStruxure BMS 的基础之一是支持开放标准。Enterprise Server 原生可与三个最流行的楼宇标准进行通信:BACnet(包括 BACnet/SC)、OPC UA Client、LonWorks 和 Modbus。

原生 BTL 认证 BACnet 支持

Enterprise Server 可与 BACnet/IP 和 BACnet MS/TP 网络直接通信。Enterprise Server 是 BTL 认证产品,可充当最先进的 BACnet 设备协议 BACnet 楼宇控制器 (B-BC)、以及 BACnet Operator Workstation (B-OWS)。此能力使其可以访问施耐德电气和其他供应商提供的全系列 BACnet 设备。在 BACnet International 首页查看 BTL 产品目录了解 BTL 列出的软件修订版本的最新详情。Enterprise Server 还可充当 BACnet 广播管理设备 (BBMD) 来促进横跨多个 IP 子网的 BACnet 系统。

BACnet/SC (Secure Connect) support

The Enterprise Server and automation servers support BACnet/SC applications as a BACnet/SC node, hub, and router. This allows the Enterprise Server and automation servers to be in BACnet/SC networks and support applications that connect BACnet/IP or MS/TP networks with BACnet/SC networks. A major benefit of BACnet/SC is that it allows more secure transport of BACnet traffic and information between BACnet/SC devices over private and public networks without the need for BBMDs, VLANs, and VPNs, because the BACnet/SC protocol uses WebSocket technology and TLS 1.3 encryption. In addition, BACnet/SC uses certificate management to help ensure only those devices authorized to be on a BACnet/SC network can operate on that network.

Native OPC UA Client support

OPC UA Client functionality is natively supported in Enterprise Server and automation servers, enabling powerful and high-capacity integration of devices or systems that have OPC UA Server capability. OPC Unified Architecture (OPC UA) is a standard originating from industrial automation and process control that provides methods intended to provide improved security, performance, and engineering efficiency. With OPC UA Client support, the EcoStruxure Building Operation software can monitor and control a wide variety of devices or systems, from Schneider Electric as well as from other companies.

原生 LonWorks 支持

Enterprise Server 与一系列 LonTalk 适配器合作,与 TP/FT-10 LonWorks 网络进行通信。集成 LonWorks 功能使其能够访问来自施耐德电气和其他供应商的 LonWorks 设备。可利用内置 LonWorks 网络管理工具从 Enterprise Server 对 LonWorks 网络进行调试、绑定和配置。无需第三方工具。为增加易用性,还支持 LNS 设备插件。这样可便于管理和维护来自施耐德电气和其他供应商的 LonWorks 网络。关于如何使用 LNS 设备插件有一些限制。

Native Modbus support

The Enterprise Server and automation servers natively integrate Modbus RS-485 client and server configurations, as well as Modbus TCP client and server. This allows full access to third-party products and the range of Schneider Electric products that communicate on the Modbus protocol, such as power meters, UPS, circuit breakers, and lighting controllers.

Modbus device types are pre-configured Modbus applications for quick and easy Modbus device integration in EcoStruxure Building Operation solutions.

Web 服务支持

Enterprise Server 支持基于开放标准(比如 SOAP 和 REST)的 Web 服务的使用,以消耗数据到 EcoStruxure BMS 中。在 Web 上使用输入的第三方数据(温度预测、能源成本)来确定站点模式、日程安排和编程。

EcoStruxure Web Services support

EcoStruxure Web Services, Schneider Electric’s Web Services standard, is natively supported in the EcoStruxure BMS servers. EcoStruxure Web Services offers extra features between compliant systems whether within Schneider Electric or other authorized systems. These features include access to semantic model, system directory browsing, read/write of current values, alarm receipt and acknowledgement, and historical trend log data. EcoStruxure Web Services requires user name and password to log on to the system.

MQTT IoT protocol support

The Enterprise Server and automation servers support MQTT as an option for publishing data to, and receiving updates from, other systems. MQTT is a messaging transport protocol that with its small footprint, light bandwidth utilization, and simplicity, is ideal for M2M and IoT communication. The MQTT capability supports communication with any MQTT broker, for example, Amazon, Microsoft, Google or IBM.

IT friendly

The EcoStruxure BMS servers communicate using the networking standards. This makes installations easy, management simple, and transactions more secure.

支持的协议
  • IP 寻址

  • TCP 通信

  • DHCP,用于轻松地配置网络

  • DNS,用于简捷地查找地址

  • HTTP/HTTPS,用于通过防火墙接入互联网,实现远程监控

  • NTP(网络时间协议),用于整个系统的时间同步

  • SMTP/SMTPS 支持基于 SSL/TLS 的身份验证,可发送时间表或报警触发的电子邮件讯息

  • SNMP,用于指定网络管理工具中的应用程序报警接收

  • WebSocket Secure (WSS) 和 TLS 1.3 加密(BACnet/SC 应用程序)

TLS support

Communication between clients and the EcoStruxure BMS servers , and between EcoStruxure BMS servers, can be encrypted using Transport Layer Security (TLS ). The servers are delivered with a default self-signed certificate. Commercial Certification Authority (CA) server certificates are supported to lower the risk of malicious information technology attacks. Use of encrypted communication can be enforced for both WorkStation and WebStation access.

表格: Windows 和 Linux 许可证的可用性

Enterprise Server 许可证

窗口

Linux

企业服务器 – 10 个自动化服务器 a

企业服务器 – 50 个自动化服务器 a

Enterprise Server - 100 个自动服务器 a

企业服务器 – 250 个自动化服务器 a

  1. 有关零件号的更多信息,请参阅“规格”一节“零件号”小节。

升级软件包许可证

窗口

Linux

升级 3.x - 10 个自动化服务器 a

-

升级 3.x - 50 个自动化服务器 a

-

升级 3.x - 100 个自动化服务器 a

-

升级 3.x - 250 个自动化服务器 a

-

升级 4.x 或 5.x - 10 个自动化服务器 a

-

升级 4.x 或 5.x - 50 个自动化服务器 a

-

升级 4.x 或 5.x - 100 个自动化服务器 a

-

升级 4.x 或 5.x - 250 个自动化服务器 a

-

  1. 有关升级软件包的更多信息,请参阅“规范”一节“升级软件包”小节。

附加选项许可证

窗口

Linux

ES Hosting AS Pack - 01 a

ES Hosting AS Pack - 10 a

ES Hosting AS Pack - 50 a

ES Hosted Node Pack - 5 a

ES Hosted Node Pack - 10 a

ES Hosted Node Pack - 25 a

ES Hosted Node Pack - 50 a

ES Hosted Node Pack - 100 a

ES Hosted Node Pack - 300 a

ES Hosted Node Pack - 600 a

EcoStruxure Web 服务使用 a

EcoStruxure Web 服务提供和使用 a

EcoStruxure Web Services 提供和使用以及历史趋势日志数据 a

Web Services(通用获取)选项 a

经由 SNMP 选项的报警通知 a

智能连接器部署许可证 a

-

个人仪表板选项 a

TimescaleDB 连接选项 a

Microsoft SQL Server 连接选项 a

AVEVA PI System 连接选项 a

Regulated Industries Compliance Pack 选项 a

PDF 签署选项 a

MQTT 选项 a

分区选项 a

SAML Authentication 选项 a

Semantic DB Plus 2 CPU 核心 a

-

Semantic DB Plus 2 CPU 核心 a

-

Semantic DB External Use Plus 2 CPU 核心 a

-

Semantic DB External Use Plus 6 CPU 核心 a

-

Sustainability Pack 选项 a

OPC UA Client 选项 a

  1. 有关附加选项的更多信息,请参阅“规范”一节“附加选项”小节。

规格

Hardware requirements
Processor power, memory, and storage capacity should be scaled upwards to accommodate targeted system size as impacted by the total quantity of automation servers and expected historical archiving. Enterprise Server is tested on many different servers with varying configurations. The typical configuration is an 8-core 3.6 GHz processor, 32 GB of memory, and SSD storage capacity of 1 TB.
Processor
Minimum: Intel Core i5 @ 2.0 GHz or equivalent
  
Recommended: Intel Core i5 @ 3.0 GHz or better
Memory
Minimum: 8 GB
  
Recommended: 16 GB or higher
Storage capacity
Minimum: 100 GB
  
Recommended: 1 TB
Storage device
Recommended: Enterprise Solid State Drive (SSD)
An Enterprise SSD is recommended to maintain the necessary speed and stability. The database and the binaries should both be installed on the Enterprise SSD.
Other devices
Microsoft mouse or compatible pointing device is required.
Software requirements
Operating systems – Enterprise Server for Windows
Microsoft Windows 10 (64-bit)
  
Microsoft Windows 11 a
  
Microsoft Windows Server 2012 R2 (64-bit)
  
Microsoft Windows Server 2016
  
Microsoft Windows Server 2019
  
Microsoft Windows Server 2022 a
The following Microsoft Windows 10 editions are supported: Pro and Enterprise.
The following Microsoft Windows 11 a editions are supported: Pro and Enterprise.
The following Microsoft Windows Server 2012 R2 editions are supported: Datacenter, Standard, Essentials, and Foundation.
The following Microsoft Windows Server 2016 editions are supported: Datacenter, Standard, and Essentials.
The following Microsoft Windows Server 2019 editions are supported: Datacenter, Standard, and Essentials.
The following Microsoft Windows Server 2022 a editions are supported: Datacenter, Standard, and Essentials.
Operating systems – Enterprise Server for Linux
OCI compliant container runtime on Linux x86-64
Quality assurance testing has been performed on, and support is provided with, Ubuntu 20.04 and 22.04 with Docker Engine version 20.10.00. Other deployment scenarios have not been tested by Schneider Electric. Product Support Services may require that potential issues can be reproduced in tested and supported environment for full support.
Required additional software – Enterprise Server for Windows
Microsoft .NET Framework 4.7.2 and later
The Microsoft .NET Framework is required by Software Administrator.
External log storage PostgreSQL option
TimescaleDB 1.2 and later
  
For use of compression: TimescaleDB 2.11 and later
  
PostgreSQL version compatible with the TimescaleDB version
Quality assurance testing has been performed by Schneider Electric with TimescaleDB and PostgreSQL installed natively in Windows 10, Windows Server 2012, 2016, and 2019. Other deployment scenarios have not been tested by Schneider Electric.
External log storage Microsoft SQL option
Microsoft SQL Server 2016 SP1 and later
The following Microsoft SQL Server editions are supported: Enterprise, Standard, and Express.
External log storage AVEVA PI System option
PI Web API 2021 SP3 and database compatible with that version
Quality assurance testing has been performed by Schneider Electric with PI Web API 2021 SP3, and database compatible with that version, installed on Windows Server 2019. Other deployment scenarios have not been tested by Schneider Electric.
Communication
TCP
Binary, port fixed, 4444
HTTP
Non-binary, port configurable, default 80
HTTPS
Encrypted supporting TLS 1.3, 1.2, 1.1 a , and 1.0 a , port configurable default 443
WSS a
Encrypted supporting TLS 1.3, port configurable
SMTP
Email sending, port configurable, default 25
SMTPS
Email sending, port configurable, default 587
SNMP
version 3
  
Application alarm distribution using trap
NTP
Time synchronization
BACnet
BACnet/IP, port configurable, default 47808
  
BACnet/SC, port configurable, no default port
  
BTL B-BC (BACnet Building Controller) a
  
BTL B-SCHUB (BACnet Secure Connect Hub) a
  
BTL B-OWS (BACnet Operator Workstation) a
OPC UA Client
Profile group UACore 1.03
Core Client Facet, Base Client Behaviour Facet a , AddressSpace Lookup Client Facet, Attribute Read Client Facet a , Attribute Write Client Facet a , DataChange Subscriber Client Facet a , Method Client Facet, UA-TCP UA-SC UA-Binary, SecurityPolicy – Basic256, SecurityPolicy – Basic256Sha256, User Token – Anonymous Facet, User Token – User Name Password Client Facet, DataAccess Client Facet, Base Event Processing Client Facet, and Historical Access Client Facet.
Supports the following LonTalk adapters:
NIC709-PCI
  
NIC709-USB
  
NIC709-USB100
  
NIC709-IP
  
NIC852
特定附加功能可采用其他协议。参见技术文档。
LNS
LNS 版本
OpenLNS
安装于 WorkStation PC 上
LonMark
Resource files version
14.00
Part numbers
Enterprise Server for Windows
Enterprise Server - 10, EcoStruxure Building Operation Enterprise Server license for a PC server, includes support for 10 automation servers , 3 concurrent clients , and 1 semantic database limited to 2 CPU cores
SXWSWESXX00010
Enterprise Server - 50, EcoStruxure Building Operation Enterprise Server license for a PC server, includes support for 50 automation servers , 3 concurrent clients , and 1 semantic database limited to 2 CPU cores
SXWSWESXX00050
Enterprise Server - 100, EcoStruxure Building Operation Enterprise Server license for a PC server, includes support for 100 automation servers , 3 concurrent clients , and 1 semantic database limited to 2 CPU cores
SXWSWESXX00100
Enterprise Server - 250, EcoStruxure Building Operation Enterprise Server license for a PC server, includes support for 250 automation servers , 3 concurrent clients , and 1 semantic database limited to 2 CPU cores
SXWSWESXX00250
Enterprise Server for Linux
Enterprise Server - 10,EcoStruxure Building Operation Enterprise Server for Linux许 可证,包括对 10 个自动化服务器和 3 个并发客户端的支持
SXWSWESLX00010
Enterprise Server - 50,EcoStruxure Building Operation Enterprise Server for Linux许 可证,包括对 50 个自动化服务器和 3 个并发客户端的支持
SXWSWESLX00050
Enterprise Server - 100,EcoStruxure Building Operation Enterprise Server for Linux许 可证,包括对 100 个自动化服务器和 3 个并发客户端的支持
SXWSWESLX00100
Enterprise Server - 250,EcoStruxure Building Operation Enterprise Server for Linux许 可证,包括对 250 个自动化服务器和 3 个并发客户端的支持
SXWSWESLX00250
Upgrade software bundles
Enterprise Server for Windows
Enterprise Server Upgrade – 10 or fewer automation servers
Upgrades Enterprise Server, with 10 or fewer hosted automation servers, from EcoStruxure Building Operation software version 3.x to 6.0.
SXWSWESUP30010
Enterprise Server Upgrade – 50 or fewer automation servers
Upgrades Enterprise Server, with 50 or fewer hosted automation servers, from EcoStruxure Building Operation software version 3.x to 6.0.
SXWSWESUP30050
Enterprise Server Upgrade – 100 or fewer automation servers
Upgrades Enterprise Server, with 100 or fewer hosted automation servers, from EcoStruxure Building Operation software version 3.x to 6.0.
SXWSWESUP30100
Enterprise Server Upgrade – 250 or fewer automation servers
Upgrades Enterprise Server, with 250 or fewer hosted automation servers, from EcoStruxure Building Operation software version 3.x to 6.0.
SXWSWESUP30250
Enterprise Server Upgrade – 10 or fewer automation servers
Upgrades Enterprise Server, with 10 or fewer hosted automation servers, from EcoStruxure Building Operation software version 4.x or 5.x to 6.0.
SXWSWESUP40010
Enterprise Server Upgrade – 50 or fewer automation servers
Upgrades Enterprise Server, with 50 or fewer hosted automation servers, from EcoStruxure Building Operation software version 4.x or 5.x to 6.0.
SXWSWESUP40050
Enterprise Server Upgrade – 100 or fewer automation servers
Upgrades Enterprise Server, with 100 or fewer hosted automation servers, from EcoStruxure Building Operation software version 4.x or 5.x to 6.0.
SXWSWESUP40100
Enterprise Server Upgrade – 250 or fewer automation servers
Upgrades Enterprise Server, with 250 or fewer hosted automation servers, from EcoStruxure Building Operation software version 4.x or 5.x to 6.0.
SXWSWESUP40250
Add-on options
Enterprise Server for Windows
ES Hosting AS Pack - 01, License to add 1 automation server
in addition to the original Enterprise Server purchased size.
SXWSWASES00001
ES Hosting AS Pack - 10, License to add 10 automation servers
in addition to the original Enterprise Server purchased size.
SXWSWASES00010
ES Hosting AS Pack - 50, License to add 50 automation servers
in addition to the original Enterprise Server purchased size.
SXWSWASES00050
ES Hosted Node Pack - 5, License to add 5 Non-SpaceLogic servers/controllers.
SXWSWNDES00005
ES Hosted Node Pack - 10, License to add 10 Non-SpaceLogic servers/controllers.
SXWSWNDES00010
ES Hosted Node Pack - 25, License to add 25 Non-SpaceLogic servers/controllers.
SXWSWNDES00025
ES Hosted Node Pack - 50, License to add 50 Non-SpaceLogic servers/controllers.
SXWSWNDES00050
ES Hosted Node Pack - 100, License to add 100 Non-SpaceLogic servers/controllers.
SXWSWNDES00100
ES Hosted Node Pack - 300, License to add 300 Non-SpaceLogic servers/controllers.
SXWSWNDES00300
ES Hosted Node Pack - 600, License to add 600 Non-SpaceLogic servers/controllers.
SXWSWNDES00600
SW-EWS-1, EcoStruxure Web Services (run-time) option
Consume only for one Enterprise Server or one Enterprise Central
SXWSWEWSX00001
SW-EWS-2, EcoStruxure Web Services (run-time) option
Serve & Consume for one Enterprise Server or one Enterprise Central
SXWSWEWSX00002
SW-EWS-3, EcoStruxure Web Services (run-time) option
Serve & Consume, plus Historical trend log data for one Enterprise Server or one Enterprise Central
SXWSWEWSX00003
SW-GWS-1, Web Services (Generic Consume) option
For one Enterprise Server or one Enterprise Central
SXWSWGWSX00001
SW-SNMP-1, Alarm notifications via SNMP option
For one Enterprise Server or one Enterprise Central
SXWSWSNMP00001*
SW-SMART-CONNECT, Smart Connector deployment license
For one Smart Connector deployment
SXWSWSCDL100001
Building Operation Personal Dashboards option, 1 per server required for users logging on to that server to have Personal Dashboard capabilities
For one Enterprise Server or one Enterprise Central
SXWSWDASH00001
SW-ESDBTS-1, TimescaleDB connection option
For one Enterprise Server
SXWSWESDBTS001*
EcoStruxure Building Operation, Microsoft SQL Server connection option
For one Enterprise Server
SXWSWESDBMS001*
EcoStruxure Building Operation, AVEVA PI System connection option
For one Enterprise Server
SXWSWESDBPI001*
Regulated Industries Compliance Pack option
For one Enterprise Server or one Enterprise Central
SXWSWCMPLPK001*
SW-ESPDF-1,Building Operation PDF 签名选项
用于一个 Enterprise Server
SXWSWESPDFSS01
SW-ESMQTT-1, MQTT option
For one Enterprise Server
SXWSWMQTTSRW01*
Building Operation Zoning option
For one Enterprise Server
SXWSWESSDZR001
SAML Authentication option
For one Enterprise Server
SXWSWESSAML001*
Semantic DB Plus 2 CPU Cores
Additional concurrent queries for one semantic database
SXWSWSTDBAC002
Semantic DB Plus 6 CPU Cores
Additional concurrent queries for one semantic database
SXWSWSTDBAC006
Semantic DB External Use Plus 2 CPU Cores
Enables queries from external tools and additional concurrent queries
SXWSWSTDBEUAC2
Semantic DB External Use Plus 6 CPU Cores
Enables queries from external tools and additional concurrent queries
SXWSWSTDBEUAC6
Sustainability Pack option
For one Enterprise Server for Windows
SXWSWESSUSPKW1*
OPC UA Client option
For one Enterprise Server for Windows
SXWSWESOPCLW01*
Enterprise Server for Linux
ES Linux 托管 AS 包 - 01,添加 1 个自动化服务器的许可证
(在原始 Enterprise Server for Linux 购买的规格的基础上)
SXWSWASESL0001
ES Linux 托管 AS 包 - 10,添加 10 个自动化服务器的许可证
(在原始 Enterprise Server for Linux 购买的规格的基础上)
SXWSWASESL0010
ES Linux 托管 AS 包 - 50,添加 50 个自动化服务器的许可证
(在原始 Enterprise Server for Linux 购买的规格的基础上)
SXWSWASESL0050
ES Linux 托管节点包 - 5,添加 5 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0005
ES Linux 托管节点包 - 10,添加 10 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0010
ES Linux 托管节点包 - 25,添加 25 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0025
ES Linux 托管节点包 - 50,添加 50 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0050
ES Linux 托管节点包 - 100,添加 100 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0100
ES Linux 托管节点包 - 300,添加 300 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0300
ES Linux 托管节点包 - 600,添加 600 个非 SpaceLogic 服务器/控制器的许可。
SXWSWNDESL0600
EcoStruxure Web Services(运行时间)选项
仅适用于一个 Enterprise Server For Linux 或一个 Enterprise Central For Linux
SXWSWEWSL00001
EcoStruxure Web Services(运行时间)选项
适用于一个 Enterprise Server For Linux 或一个 Enterprise Central For Linux
SXWSWEWSL00002
EcoStruxure Web Services(运行时间)选项
服务和消费,外加历史趋势日志数据,用于一个 Enterprise Server for Linux 或一个 Enterprise Central for Linux
SXWSWEWSL00003
Web Services(通用获取)选项
适用于一个 Enterprise Server For Linux 或一个 Enterprise Central For Linux
SXWSWGWSL00001
经由 SNMP 选项的报警通知
适用于一个 Enterprise Server For Linux 或一个 Enterprise Central For Linux
SXWSWSNMPL0001
个人仪表板选项,每台服务器需要 1 个,让登录该服务器的用户具有个人仪表板功能
适用于一个 Enterprise Server For Linux 或一个 Enterprise Central For Linux
SXWSWDASHL0001
TimescaleDB 连接选项
适用于一个 Enterprise Server for Linux
SXWSWESDBTSL01*
Microsoft SQL Server 连接选项
适用于一个 Enterprise Server for Linux
SXWSWESDBMSL01*
AVEVA PI System 连接选项
适用于一个 Enterprise Server for Linux
SXWSWESDBPIL01*
Regulated Industries Compliance Pack option
For one Enterprise Server for Linux or one Enterprise Central for Linux
SXWSWCMPLPKL01*
PDF 签署选项
适用于一个 Enterprise Server for Linux
SXWSWESPDFSSL1
MQTT 选项
适用于一个 Enterprise Server for Linux
SXWSWMQTTSRWL1*
分区选项
适用于一个 Enterprise Server for Linux
SXWSWESSDZRL01
SAML 认证选项
适用于一个 Enterprise Server for Linux
SXWSWESSAMLL01*
Sustainability Pack option
For one Enterprise Server for Linux
SXWSWESSUSPKL1*
OPC UA Client option
For one Enterprise Server for Linux
SXWSWESOPCLL01*