SpaceLogic Sensor Interfaces

37 Topic(s)
Use the filters below to limit the number of search hits.
Products
Display all
WorkStation
WebStation
Graphics Editor
WebReports
Script Editor
Function Block Editor
Device Administrator
​License Server
​License Administrator
Software Administrator
Enterprise Server
PS-24V
AO-8
AO-V-8
DO-FA-12
DO-FC-8
UI-16
DI-16
UI-8/AO-4
UI-8/AO-V-4
UI-8/DO-FC-4
WebHelp
Automation Server
Administrator Tools
Power Supply
Central IO Modules
Project Configuration Server
Mobile Apps
Technician Tool for iOS
Technician Tool for Android
RTD-DI-16
Support Tools
Registration Portal
Transition
TAC Vista Conversion Tool
AS-P
AD v1
Project Configuration Tool
SmartXKiosk
Automation Servers
Continuum Conversion Tool
AS-B
Automation Server Smoke Control
AS-P Smoke Control
AD v2
MP-C
MP-V
Advanced Display
Enterprise Central
SpaceLogic Sensor
Commission
BACnet/IP Devices
RP-C
IP-IO
AD v3
HMI Kiosk
RP-C-EXT-0-10V-4-PD
RP-C-EXT-BL-2-LV-PD
RP-C-EXT-BL-4-HV-PD
RP-C-EXT-DALI-M-PD
RP-C-EXT-MS-BLE
Engage
RP Controller Expansion Modules
MP-C Smoke Control
MP-V Smoke Control
IP-IO Smoke Control
RP-C-EXT-DALI
RP-C-EXT-0-10V-4
RP-C-EXT-BL-SMI-4-HV-PD
RP-C-EXT-BL-SMI-2-LV-PD
RP-C-EXT-REL-4
RP-C-RC-BLE
RP-C-EXT-KNX
Wireless Adapter - Advanced
CRS-HH-REL-10
Touch Screens
Operator Display
Builder for Function Block
All EcoStruxure BMS Products
Information Type
Display all
Concept
User Interface
Troubleshooting
Developers Reference
Specifications
How to
Hardware Installation
Topic
Modified
Rating
Turning the Lights On and Off
In the SpaceLogic Sensor Touchscreen Display model, you turn lights on and off in order to increase or decrease living space illumination and conserve energy. You enable this feature using the Allow light control property in the Display object. You then use the Toggle lights, Button (1-12) function in the Button and Scene Configuration page to toggle the lights on and off. You can also use the Lighting mode property to allow the integrator to perform a Digital toggle for the lighting control menu as described here.
7/23/2021
Dimming the Lights
In the SpaceLogic Sensor Touchscreen Display model, you dim the lights in order to increase or decrease living space illumination and conserve energy. You enable this feature using the Allow light control property in the Display object. You then use the Lighting mode property to allow the integrator to select Analog adjustable for the lighting control menu.
7/23/2021
Fully Opening and Closing the Blinds
In the SpaceLogic Sensor Touchscreen Display model, you fully open and close the blinds in order to increase or decrease living space illumination and conserve energy. You enable this feature using the Allow blind control property in the Display object. You then use the Toggle blinds, Button (1-12) function property on the Button and Scene Configuration page to toggle the blinds fully open and closed. You can also use the Blind control mode property to allow the integrator to perform a Digital toggle control for the blind control menu as described here.
7/23/2021
Incrementally Adjusting the Blinds
In the SpaceLogic Sensor Touchscreen Display model, you incrementally adjust the blinds in order to increase or decrease living space illumination and conserve energy. You enable this feature using the Allow blind control property in the Display object. You then use the Blind angle mode property to allow the integrator to select Analog adjustable and manipulate the blind control menu.
7/23/2021
Accessing the Integrator Menu
You access the Integrator menu to view information pages in the SpaceLogic Sensor Touchscreen Display Model. You enable the page individually with the Allow sensors information page, Allow device information page, Allow parent information page, and Allow custom information page in the Display object. If the individual pages are not visible in the integrator menu, the property is not enabled and you are not permitted to access that page.
7/23/2021
Backlighting in the SpaceLogic Sensor 3-Button Cover Model
When the room occupant presses the buttons on the SmartX Sensor 3-Button Cover model to increase or decrease the temperature setpoint, the backlight changes from deep blue at the low end of the range, to deep red at the top end of the range. Each button push causes a 10% increase or decrease in the range. The backlight flashes rapidly three time to indicate the top or bottom of range has been reached.
7/23/2021
Changing Heating and Cooling Mode Settings
In the SpaceLogic Sensor LCD Temperature Sensor model, you change the heating and cooling mode settings to enhance living space comfort. You enable this feature by choosing the Display object Heating cooling status property and its relevant option.
7/23/2021
Changing the Degree Type
In the SpaceLogic Sensor LCD Temperature Sensor model, you change the degree type to either Celsius or Fahrenheit to view the temperature in the desired units. You enable this feature by choosing the Display object Temperature units property and its Fahrenheit or Celsius option.
7/23/2021
Changing the Fan Speed
In the SpaceLogic Sensor LCD Temperature Sensor model, you change the fan speed to change the air flow in the designated living space. You enable this feature by choosing the Display object Fan speed property and its appropriate setting, such as Off, Level-1-Low-On, or Level-2-High.
7/23/2021
Changing the Heating and Cooling Mode
You configure valid HVAC modes in the Display object HVAC mode property with values such as Auto, Heat, and Cool. The Display object Allowed HVAC modes property determines what modes are available such as Auto, Auto-Heat, Auto-Cool, and Auto-Heat-Cool. As long as this feature is supported by the control application, this allows the room occupant to change the HVAC mode.
7/23/2021