Use the Trend Chart toolbar to manage the trend chart and its series.
Button |
Description |
|
Save Click to save the settings you have changed in the trend chart. Pour plus d'informations, voir Saving Current Trend Chart Settings . |
|
Zoom to fit Click to resize the trend logs to fit in the browser window. Pour plus d'informations, voir Zoom to Fit . |
|
Zoom tool Click to zoom in the trend log area. Pour plus d'informations, voir Zooming In an Area of a Trend Chart . |
|
Pan tool Click to drag the chart area upwards or downwards. |
|
Hour Click to set the scale of the x-axis to one hour. Pour plus d'informations, voir Displaying Specific Time Spans of a Trend Chart in WebStation . |
|
Day Click to set the scale of the x-axis to one day. Pour plus d'informations, voir Displaying Specific Time Spans of a Trend Chart in WebStation . |
|
Week Click to set the scale of the x axis to one week. Pour plus d'informations, voir Displaying Specific Time Spans of a Trend Chart in WebStation . |
|
Month Click to set the scale of the x-axis to one month. Pour plus d'informations, voir Displaying Specific Time Spans of a Trend Chart in WebStation . |
|
Year Click to set the scale of the x-axis to one year. Pour plus d'informations, voir Displaying Specific Time Spans of a Trend Chart in WebStation . |
|
Go to date Click to open a calendar to navigate to a specific date. |
|
Show alarm guides Click to display alarm limits. Pour plus d'informations, voir Display Alarm Limits in a Trend Chart in WebStation . |
|
Settings Click to open the Settings dialog box for the trend chart where you can configure the trend chart axis, series, and calculations. Pour plus d'informations, voir Trend Chart Settings Dialog Box – X Axis Tab . Pour plus d'informations, voir Trend Chart Settings Dialog Box – Left Axis Tab . Pour plus d'informations, voir Trend Chart Settings Dialog Box – Series Tab . |
|
Automatic scroll Click to automatically receive the latest value. Pour plus d'informations, voir Automatically Updating Values in a Trend Chart Series . |
|
Show tooltip for the closest item Click to view the value closest to the pointer. Pour plus d'informations, voir Showing Tooltip for the Closest Item . |
|
Show tooltips for all series Click to view all tooltips for all series when you want to compare values between trend chart series at a specific time. Pour plus d'informations, voir Show Tooltips for All Series in a Trend Chart . |
|
Show as list Click to show the trend series in the trend chart as lists. Pour plus d'informations, voir Showing Trend Chart Series as a List . |
|
Add Click to add a new series to the trend chart. Pour plus d'informations, voir Adding a Trend Chart Series to a Trend Chart in WebStation . |