EcoStruxure Building Operation Software Licensing Overview

Licenses are needed for EcoStruxure Building Operation products and features that run on Windows.

EcoStruxure Building Operation Software License Components

To install and use EcoStruxure Building Operation software licenses, you need three main components:

  • License Activation Server

  • License Server

  • License Administrator

Para obtener más información, consulte EcoStruxure Building Operation Software License Components .

EcoStruxure Building Operation Software and Features that Require Licenses

Refer to the document Part Number Summary and Hardware Software Matrix for software and features that need licenses, available on Schneider Electric Extranet.

Information regarding licenses can also be found on the specification sheets:

WorkStation Para obtener más información, consulte WorkStation .

WebStation Para obtener más información, consulte WebStation .

AS-P Para obtener más información, consulte SmartX AS-P Server .

AS-B Para obtener más información, consulte SmartX AS-B Server .

Enterprise Central Para obtener más información, consulte Enterprise Central .

Enterprise Server Para obtener más información, consulte Enterprise Server .

Compliance Pack Para obtener más información, consulte Paquete de cumplimiento de Enterprise Server .

EcoStruxure Building Operation Software Licensing Installation and Location

It is recommended that License Administrator and License Server run on the same computer as Enterprise Server or Enterprise Central that use the licenses.

Para obtener más información, consulte EcoStruxure Building Operation Software Licensing Installation and Location .

EcoStruxure Building Operation Licensing Workflow

Use this workflow to install and activate licenses on the License Administrator.

Para obtener más información, consulte EcoStruxure Building Operation Software Licensing Workflow .

EcoStruxure Building Operation Software License Distribution and Selection

EcoStruxure Building Operation software licenses are distributed and selected from License Server.

Para obtener más información, consulte EcoStruxure Building Operation Software License Distribution and Selection .

Inherited Licenses

Inherited licenses are used system-wide in multi-server systems.

Para obtener más información, consulte Inherited Licenses .

EcoStruxure Building Operation Software Feature Licenses Strings

The feature strings are used when you troubleshoot a license problem. The strings are visible in the Diagnostic tab of License Administrator.

Para obtener más información, consulte EcoStruxure Building Operation Software Feature License Strings .

EcoStruxure Building Operation Software License Maintenance

You can backup and restore EcoStruxure Building Operation software licenses as well as relocate and replace the License Server.

Para obtener más información, consulte EcoStruxure Building Operation Software License Maintenance .

License Server Configuration and Diagnostics

You can configure the licensing components and do diagnostics on your system regarding licensing.

  • EcoStruxure Building Operation Software License Maintenance
  • EcoStruxure Building Operation Software License Components
  • EcoStruxture Building Operation Software and Features that Require Licenses
  • EcoStruxure Building Operation Software Licensing Workflow
  • EcoStruxure Building Operation Software License Distribution and Selection
  • Inherited Licenses
  • EcoStruxure Building Operation Software Licensing Installation and Location
  • EcoStruxure Building Operation Software Feature License Strings