产品: WebStation
功能: Dashboards
产品版本: 3.0, 3.1, 3.2, 3.3, 2022, 2023
2024/3/14

配置点值

可配置点值以将点的当前值显示为数值。

显示更多
action_close

Dashboard widgets are small applications in a dashboard. Dashboard widgets are the main components in a dashboard and present graphical information from your system.

You can create one or many dashboard widgets in a dashboard. Dashboard widgets can only be created in a dashboard in WebStation.

Ready to use

All dashboard widgets are ready to use. The only thing you must do is add the trend log, variable, alarm, or event you want to display in the dashboard widget. All dashboard widgets have default setting for color and different layout components, but you can also configure them to suit your needs. For example, you can add captions to the widget itself or the x- and y-axis in diagram, you can use different colors for different values or value ranges in a gauge.

Clone Widgets and Rebind Widget References

You can clone widgets and rebind widgets references.

有关更多信息,请参阅 克隆小部件和重新绑定小部件引用 .

Empty Space

Empty space is not a dashboard widget but a way to create empty spaces between dashboard widgets. Empty spaces are used when you do the layout of a dashboard.

Alarm Count

An alarm count displays the number of alarms from the EcoStruxure Building Operation system.

有关更多信息,请参阅 警报计数 .

Alarm Pareto Chart

An alarm Pareto chart is a graphical representation of alarms represented by bars but also by a cumulative line. An alarm pareto chart gives you a quick overview of the most common causes of alarms.

有关更多信息,请参阅 警报帕累托图 .

Alarm Pie

An alarm pie chart is a circular graphic divided into slices to illustrate proportions of alarms.

有关更多信息,请参阅 警报饼图 .

Alarm Sankey Chart

An alarm Sankey chart is used to graphically present a Sankey chart of the alarms in the EcoStruxure Building Operation system.

有关更多信息,请参阅 警报桑基图 .

Event Pareto Chart

An event Pareto chart is a graphical representation where the events are represented by bars but also by a cumulative line. An event pareto chart gives you a quick overview of the most common events.

有关更多信息,请参阅 事件帕累托图 .

Event Pie

An event pie chart is a circular graphic divided into slices to illustrate proportions of events.

有关更多信息,请参阅 Event Pie .

Event Rate Chart

An event rate chart is a graphical representation of event rates represented by bars.

有关更多信息,请参阅 事件发生率图 .

Event Sankey Chart

An events Sankey chart is used to graphically present a Sankey chart of the events in the EcoStruxure Building Operation system.

有关更多信息,请参阅 事件桑基图 .

Heat Map

A heat map is a graphical representation of data where the values contained in a matrix are represented as colors.

有关更多信息,请参阅 热图 .

Log Gauge

A log gauge displays trend log values in a gauge.

有关更多信息,请参阅 日志测量仪 .

Log Pie

A log pie chart is a circular graphic divided into slices to illustrate proportions of trend logs.

有关更多信息,请参阅 日志饼 .

Log Value

A log value displays one or many trend log values as numerical values.

有关更多信息,请参阅 记录值 .

Period Chart

A period chart is used to compare trend logs over different time periods.

有关更多信息,请参阅 周期图 .

Period over Period Chart

A period chart is used to compare trend logs over different time periods.

有关更多信息,请参阅 周期图表 .

Point Gauge

A point gauge is used to graphically display a current value in a gauge.

有关更多信息,请参阅 点测量仪 .

Point Pie

A point pie chart is a circular graphic divided into slices to illustrate proportion of values.

有关更多信息,请参阅 点饼 .

Point Value

A point value is used to display the present value of one or many variables as a numerical value.

有关更多信息,请参阅 点值 .

XY Plot

A XY plot, also called a scatter plot, is used to display values for two trend logs.

有关更多信息,请参阅 XY 绘图 .

Browse

Use Browse to navigate to a graphic or a hyperlink that you want to add to a dashboard.

Dynamic Dashboad Widget

Dynamic widgets is a way to automatically add graphics to a dashboard using a search function.

有关更多信息,请参阅 动态小部件 .

Graphics

Graphics can be added to a dashboard.

有关更多信息,请参阅 仪表板中的图形 .

Hyperlinks

Hyperlinks can also be added to a dashboard. To be able to display the content of the hyperlink, you must enable external content to be embedded in WebStation.

有关更多信息,请参阅 Configuring Security in WebStation using WorkStation .

配置和编辑点值
  1. 点击 配置 或点击 设置 按钮

     
    action_zoom_plus_stroke

  2. 点击 添加 添加变量。

  3. 显示变量 框中,键入要显示的变量。

  4. 图标 框中,选择要显示在变量前方的图标。 box, select an icon to be displayed in front of the variable.

  5. 要更改默认颜色,点击 编辑按钮

     
    action_zoom_plus_stroke

  6. 点辅助线系列属性 对话框中,向下滚动到 辅助线

  7. 点击 添加

  8. 框中,输入值。

  9. 颜色 框中,输入趋势日志的颜色。

  10. 点击 确定

  11. 标题 框中,键入标题。

  12. 标题 链接 框中,输入对于点测量仪相关的对象的链接。

  13. 点击 确定

  • 仪表板的工作方式
  • Dashboard Widgets
  • 点值
  • 点值属性对话框
  • 向仪表板添加小部件