Dashboard widgets are small applications in a dashboard. Dashboard widgets are the main components in a dashboard and present graphical information from your system.
You can create one or many dashboard widgets in a dashboard. Dashboard widgets can only be created in a dashboard in WebStation.
All dashboard widgets are ready to use. The only thing you must do is add the trend log, variable, alarm, or event you want to display in the dashboard widget. All dashboard widgets have default setting for color and different layout components, but you can also configure them to suit your needs. For example, you can add captions to the widget itself or the x- and y-axis in diagram, you can use different colors for different values or value ranges in a gauge.
You can clone widgets and rebind widgets references.
Per maggior informazioni, consulta Clona widget e riassocia riferimenti widget .
Empty space is not a dashboard widget but a way to create empty spaces between dashboard widgets. Empty spaces are used when you do the layout of a dashboard.
An alarm count displays the number of alarms from the EcoStruxure Building Operation system.
Per maggior informazioni, consulta Conteggio allarmi .
An alarm Pareto chart is a graphical representation of alarms represented by bars but also by a cumulative line. An alarm pareto chart gives you a quick overview of the most common causes of alarms.
Per maggior informazioni, consulta Grafico di Pareto degli allarmi .
An alarm pie chart is a circular graphic divided into slices to illustrate proportions of alarms.
Per maggior informazioni, consulta Grafico a torta allarmi .
An alarm Sankey chart is used to graphically present a Sankey chart of the alarms in the EcoStruxure Building Operation system.
Per maggior informazioni, consulta Diagramma di Sankey allarmi .
An event Pareto chart is a graphical representation where the events are represented by bars but also by a cumulative line. An event pareto chart gives you a quick overview of the most common events.
Per maggior informazioni, consulta Grafico di Pareto degli eventi .
An event pie chart is a circular graphic divided into slices to illustrate proportions of events.
Per maggior informazioni, consulta Event Pie .
An event rate chart is a graphical representation of event rates represented by bars.
Per maggior informazioni, consulta Classifica tasso eventi .
An events Sankey chart is used to graphically present a Sankey chart of the events in the EcoStruxure Building Operation system.
Per maggior informazioni, consulta Diagramma di Sankey degli eventi .
A heat map is a graphical representation of data where the values contained in a matrix are represented as colors.
Per maggior informazioni, consulta Mappa di calore .
A log gauge displays trend log values in a gauge.
Per maggior informazioni, consulta Misuratore di registro .
A log pie chart is a circular graphic divided into slices to illustrate proportions of trend logs.
Per maggior informazioni, consulta Torta di registro .
A log value displays one or many trend log values as numerical values.
Per maggior informazioni, consulta Valore registro .
A period chart is used to compare trend logs over different time periods.
Per maggior informazioni, consulta Grafico periodo .
A period chart is used to compare trend logs over different time periods.
Per maggior informazioni, consulta Grafico Periodo su Periodo .
A point gauge is used to graphically display a current value in a gauge.
Per maggior informazioni, consulta Misuratore dei punti .
A point pie chart is a circular graphic divided into slices to illustrate proportion of values.
Per maggior informazioni, consulta Torta dei punti .
A point value is used to display the present value of one or many variables as a numerical value.
Per maggior informazioni, consulta Valore punto .
A XY plot, also called a scatter plot, is used to display values for two trend logs.
Per maggior informazioni, consulta Grafico XY .
Dynamic widgets is a way to automatically add graphics to a dashboard using a search function.
Per maggior informazioni, consulta Widget dinamici .
Graphics can be added to a dashboard.
Per maggior informazioni, consulta Grafica nei dashboard .
Hyperlinks can also be added to a dashboard. To be able to display the content of the hyperlink, you must enable external content to be embedded in WebStation.
Per maggior informazioni, consulta Configuring Security in WebStation using WorkStation .